促销!

12VDC Power Supply 35W 3A ACDC LED Power Supply Meanwell-APV-35-12(35W-12V)

原价为:$16.50。当前价格为:$15.00。

Product Features

12VDC Power Supply Meanwell APV-35-12 LED Powe Supply  

#Features
Constant voltage mode for APV series
Universal AC input : 90~264VAC
Withstand 300VAC surge input for 5 secs. (APV-25/35)
Isolation class II,no F.G.
Class 2 power unit / Pass LPS
(except for APV/APC-8,APC-25-350 and APC-35-350/500)
Fully isolated plastic case with IP42 level
Protections: Short Circuit / Overload (only for APV series)

Constant voltage mode power supply
Universal AC input Full range
Withstand 300VAC Surge input for 5 seconds
Protections: Short circuit Over load Over voltage
Fully isolated plastic case
Cooling by free air convection
Small and compact size
IP42 design
Class 2 power unit
Pass LPS
100% full load burn-in test
Low cost, high reliability
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)(Note.10)

 

Specifications

12VDC Power Supply 35W Single Output Switching Power Supply

#Introduction of Meanwell APV Series 35W -12/24V)
The APV is the entry-level products. All products are divided into constant voltage and constant current applications.
Most DC 12V and 24V can also be used with general light bar/light strip or advertising light box application. Moreover,other output voltage models are also available for choice and waterproof function is available for LP series .Other constant current application can be used according to the COB LED or SMD
LED specifications selected. Currently,the Driver current range can cover from 250/350/500/700/1050/1400mA to maximum operate up to 3150 mA (150W)for all kinds of indoor lighting applications.

#Specification

SpecificationMeanwell Power Supply APV-35-12
#OutputDC Voltage12V
Working VoltageRated Current3A
Current Range0-3A
Rated Power36W
RIPPLE NOISE (max. Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3 ±5.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±2.0%
SETUP, RISE TIME Note.6 1500ms, 40ms/230VAC, 1500ms,40ms/115VAC at full load
HOLD UP TIME (Typ.) 20ms/230VAC , 12ms/115VAC at full load
#InputVOLTAGE RANGE Note.490-264VAC, 127-370VDC
FREQUENCY RANGE 47-63Hz
EFFICIENCY (Typ.) 83%
AC CURRENT 0.5A/230VAC, 0.75A/115VAC
INRUSH CURRENT(Typ.) COLD START 45A(twidth=440us measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER. 6 units(circuit breaker of type B)/ 10 units (circuit breaker of type C)at 230VAC
LEAKAGE CURRENT 0.25mA/ 240VAC
#ProtectionOver Load110%~160% rated output power Protection type Hiccup mode, recovers automatically after fault condition is removed
Over Voltage5.75~6.95V /13.8~16.2V/17.25~21V/27~32.4V Protection type: Shut down o/p voltage, re-power on to recover
#EnvironmentWORKING TEMP.-30 ~ 70°C (Refer to "Derating Curve")
WORKING HUMIDITY20~90% RH non-condensing
STORAGE TEMP., HUMIDITY-40~+80℃,10~95%RH
TEMP. COEFFICIENT±0.03%/℃(0~50℃)
VIBRATION10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
#Safety & EMC StandardsSAFETY STANDARDSUL8750 ,CSA-C22.2 No.250.0-13, BIS IS15885, EAC TP TC 004,IP42,BS EN/EN 62368-1 approved
WITHSTAND VOLTAGEI/P-O/P: 3KVAC
ISOLATION RESISTANCEI/P-O/P:>100M Ohms/500VDC/25C/70% RH
EMC EMISSIONCompliance to BS EN/EN55032,BS EN/EN61000-3-2 Class A,BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITYCompliance to BS EN/EN55035, BS EN/EN61000-4-2,3,4,5,6,8, 11; light industry level(surge 2KV), EAC TP TC 020
MTBF5489.6K hrs min. Telcordia SR-332(Bellcore); 600.8K hrs min. MIL-HDBK-217F(25C)
DIMENSION84*57*29.5mm (L*W*H)
PACKING72pcs / 14Kg/ 0.92CUFT
Note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf 47uf parallel capacitor.
3. Tolerance includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com/Upload/PDF/EMI_statement_en.pdf)
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. Products sourced from the Americas regions may not have the ENEC/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
9. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
10. This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)
# Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

#Other Optional Voltage
5V 12V 15V 24V 36V

#Applications:
Factory Automation Equipment /Home Interiors/Industrial Equipment/Sign Lighting
Stage & Theaters/Strip Lights/Trade Shows

#Warranty 2 years

# Meanwell APV-35 Power Supply Specification

Meanwell Powe Supply APV-35 Specification

#Meanwell APV-35 Power Supply user’s Manual

Meanwell Powe Supply user's Manual

 