Meanwell 12V Power Supply 60W 5A LPV-60 IP67 waterproof input Volt 90~264Vac output Volt 5V12V15V24V36V48Vdc UL&EMC List
#12VDC Power Supply 60W 5A Meanwell LPV-60-12(60W-12V) Single Output Switching Power Supply
#Meanwell Power Supply LPV-60 Safety&EMC Standard List
#SAFETY STANDARDS UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(Note 12),EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved
#EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
#EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020

Specification Datasheet Meanwell Power Supply LPV-60-12
#Output DC Voltage 12V
Working Voltage Rated Current 5A
Current Range 0~5A
Rated Power 60W
Ripple Noise (max. Note.2 120mVp-p ±5.0%
Voltage TOLERANCE Note.3 ±5.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±2.0%
SETUP, RISE TIME Note.6 500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load(for 5-36V); 500ms, 30ms /230VAC 500ms, 30ms/ 115VAC at full load(for 48V)
HOLD UP TIME (Typ.) 50ms/230VAC 16ms/115VAC at full load
#Input VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 83%
AC CURRENT 1.2A/115VAC 1A/230VAC
INRUSH CURRENT(Typ.) COLD START 60A(twidth=525μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER. 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT 0.25mA / 240VAC
#Protection Over Load 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
#Environment WORKING TEMP. -30 ~ +70°C (Refer to "Derating Curve")
WORKING HUMIDITY 20~90% RH non-condensing
STORAGE TEMP., HUMIDITY -40~+80°C, 10~ 95% RH
TEMP. COEFFICIENT ±0.03%/°C (0~50°C)
VIBRATION 10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
#Safety & EMC Standards SAFETY STANDARDS UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(Note 12),
EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved
WITHSTAND VOLTAGE I/P-O/P: 3KVAC
ISOLATION RESISTANCE 1/P-0/P:>100M Ohms / 500VDC/25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
MTBF 5188.4K hrs min. Telcordia SR-332 (Bellcore) ; 732.1Khrs min. MIL-HDBK-217F (25°C)
DIMENSION 162.5*42.5*32mm (L*W*H)
PACKING 0.4Kg; 32pcs/13.8Kg/0.63CUFT
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
8. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft). 9. Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
10. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
12. Products sourced from the China regions may not have the BIS logo, please contact your MEAN WELL sales for more information
#Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
#Meanwell Power Supply Specifications
meanwell LPV-60-12-specification
#Meanwell Power Supply User’s Manual